  4. ARACAM: A RGB-D Multi-View Photogrammetry System for Lower Limb 3D Reconstruction Applications

ARACAM: A RGB-D Multi-View Photogrammetry System for Lower Limb 3D Reconstruction Applications

Thumbnail Image
Download
Name

sensors-22-02443.pdf

Size

21.54 MB

Format

Adobe PDF

Checksum (MD5)

589fb248c01ce37eed87a69932fd8430

Download all files submitted through automated deposit
packager-623c846c.zip (21.29 MB)
Author(s)
Barreto, Marco A.
•
Perez-Gonzalez, Jorge
•
Herr, Hugh M.
•
Huegel, Joel C.
Date Issued
March 22, 2022
Publisher
Multidisciplinary Digital Publishing Institute
Citation
Sensors 22 (7): 2443 (2022)
Version
Final published version
Abstract
In the world, there is a growing need for lower limb prostheses due to a rising number of amputations caused primarily, by diabetic foot. Researchers enable functional and comfortable prostheses through prosthetic design by integrating new technologies applied to the traditional handcrafted method for prosthesis fabrication that is still current. That is why computer vision shows to be a promising tool for the integration of 3D reconstruction that may be useful for prosthetic design. This work has the objective to design, prototype, and test a functional system to scan plaster cast molds, which may serve as a platform for future technologies for lower limb reconstruction applications. The image capture system comprises 5 stereoscopic color and depth cameras, each with 4 DOF mountings on an enveloping frame, as well as algorithms for calibration, segmentation, registration, and surface reconstruction. The segmentation metrics of dice coefficient and Hausdorff distance (HD) show strong visual similarity with an average similarity of 87% and average error of 6.40 mm, respectively. Moving forward, the system was tested on a known 3D printed model obtained from a computer tomography scan to which comparison results via HD show an average error of ≤1.93 mm thereby making the system competitive against the systems reviewed from the state-of-the-art.
MIT Department
McGovern Institute for Brain Research at MIT
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/141372
DOI of Published Version
https://doi.org/10.3390/s22072443
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.