Enabling Force Sensing During Ground Locomotion: A Bio-Inspired, Multi-Axis, Composite Force Sensor Using Discrete Pressure Mapping
Name
MultiAxisForceSensor-IEEE-Revised-final.pdf
Description
Main article
Size
4.67 MB
Format
Adobe PDF
Checksum (MD5)
adc6280ded4a29f94b64b4e4cc1cdf9b
Author(s) •
Chuah, Meng Yee
Kim, Sangbae
Date Issued
March 2014
Journal
IEEE Sensors Journal
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Chuah, Meng Yee, and Sangbae Kim. “Enabling Force Sensing During Ground Locomotion: A Bio-Inspired, Multi-Axis, Composite Force Sensor Using Discrete Pressure Mapping.” IEEE Sensors J. 14, no. 5 (May 2014): 1693–1703.
Version
Author's final manuscript
Abstract
This paper presents a new force sensor design approach that maps the local sampling of pressure inside a composite polymeric footpad to forces in three axes, designed for running robots. Conventional multiaxis force sensors made of heavy metallic materials tend to be too bulky and heavy to be fitted in the feet of legged robots, and vulnerable to inertial noise upon high acceleration. To satisfy the requirements for high speed running, which include mitigating high impact forces, protecting the sensors from ground collision, and enhancing traction, these stiff sensors should be paired with additional layers of durable, soft materials; but this also degrades the integrity of the foot structure. The proposed foot sensor is manufactured as a monolithic, composite structure composed of an array of barometric pressure sensors completely embedded in a protective polyurethane rubber layer. This composite architecture allows the layers to provide compliance and traction for foot collision while the deformation and the sampled pressure distribution of the structure can be mapped into three axis force measurement. Normal and shear forces can be measured upon contact with the ground, which causes the footpad to deform and change the readings of the individual pressure sensors in the array. A one-time training process using an artificial neural network is all that is necessary to relate the normal and shear forces with the multiaxis foot sensor output. The results show that the sensor can predict normal forces in the Z-axis up to 300 N with a root mean squared error of 0.66% and up to 80 N in the X- and Y-axis. The experiment results demonstrates a proof-of-concept for a lightweight, low cost, yet robust footpad sensor suitable for use in legged robots undergoing ground locomotion.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1109/JSEN.2014.2299805