Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. A model of muscle-tendon function in human walking

A model of muscle-tendon function in human walking

Thumbnail Image
Download
Name

Endo-2009-A model of muscle-tendon function in human walking.pdf

Size

328.09 KB

Format

Adobe PDF

Checksum (MD5)

e1d7ed468866df15ed9ccb683d48a7d4

Author(s)
Endo, Ken
•
Herr, Hugh M
Date Issued
July 2009
Journal
IEEE International Conference on Robotics and Automation, 2009. ICRA '09.
Publisher
Institute of Electrical and Electronics Engineers
Citation
Endo, K., and H. Herr. “A model of muscle-tendon function in human walking.” Robotics and Automation, 2009. ICRA '09. IEEE International Conference on. 2009. 1909-1915. © 2009 IEEE
Version
Final published version
Abstract
In this paper, we study the mechanical behavior of leg muscles and tendons during human walking in order to motivate the design of economical robotic legs. We hypothesize that quasi-passive, series-elastic clutch units spanning the knee joint in a musculoskeletal arrangement can capture the dominant mechanical behaviors of the human knee in level-ground walking. Since the mechanical work done by the knee joint throughout a level-ground self-selected-speed walking cycle is negative, and since there is no element capable of dissipating mechanical energy in the musculoskeletal model, biarticular elements would necessarily need to transfer energy from the knee joint to hip and/or ankle joints. This mechanism would reduce the necessary actuator work and improve the mechanical economy of a human-like walking robot. As a preliminary evaluation of these hypotheses, we vary model parameters, or spring constants and clutch engagement times, using an optimization scheme that minimizes ankle and hip actuator positive work while still maintaining human-like knee mechanics. For model evaluation, kinetic and kinematic gait data were employed from one study participant walking across a level-ground surface at a self-selected gait speed. With this under-actuated leg model, we find good agreement between the model's quasi-passive knee torque and experimental knee values, suggesting that a knee actuator is not necessary for level-ground robotic ambulation at self-selected gait speeds.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Media Laboratory
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Massachusetts Institute of Technology. Media Laboratory. Biomechatronics Group
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/54701
DOI of Published Version
http://dx.doi.org/10.1109/ROBOT.2009.5152622
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.