Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. True batch reverse osmosis prototype: model validation and energy savings

True batch reverse osmosis prototype: model validation and energy savings

Thumbnail Image
Download
Name

IDAWC2019-Wei.pdf

Size

644.76 KB

Format

Adobe PDF

Checksum (MD5)

03d67199ea5a8fa9e0c6d61857313a29

Author(s)
Wei, Quantum J.
•
Tucker, Carson I.
•
Wu, Priscilla J.
•
Trueworthy, Ali M.
•
Tow, Emily W.
•
Lienhard, John H
Date Issued
October 2019
Journal
The International Desalination Association World Congress on Desalination and Water Reuse 2019/Dubai, UAE
Publisher
International Desalination Association
Citation
Wei, Quantum J. et al. "True batch reverse osmosis prototype: model validation and energy savings." The International Desalination Association World Congress on Desalination and Water Reuse 2019/Dubai, UAE, October 2019, Dubai, United Arab Emirates, International Desalination Association, October 2019
Version
Author's final manuscript
Abstract
In this study, we tested a bench-scale prototype of a true batch reverse osmosis (RO) system using a flexible bladder and a 2.5 in. (6.4cm) spiral wound membrane element. In theory, batch RO systems can achieve the lowest practical energy consumption by varying feed pressure over time. However, this is the first study to validate batch models by measuring the hydraulic work of both the high pressure pump and the circulation pump. The experimental measurements agree well with the model (error < 3%) after accounting for concentration polarization. We used the validated model to calculate the energy savings of true batch systems at higher salinities and recovery ratios. Previous studies assumed that a batch RO plant would operate at the same flux and steady-state feed salinity as a comparable continuous RO plant. In order to match the permeate production of a continuous RO plant, a batch RO plant must operate at an elevated flux to offset its intermittent permeate production. A batch RO plant will operate at a steady-state feed salinity higher than the plant’s intake feed salinity due to salt retention between batch cycles. As a result of these practical inefficiencies, the energy savings achievable by true batch systems are less than previously thought, but still significant at relatively high recoveries. At 50% recovery of seawater feed, a batch system could save 11% of the energy consumed by a continuous RO system while still maintaining the same level of permeate production. We have demonstrated the successful operation of a true batch system and shown that it can indeed reduce energy consumption. Keywords: batch reserve osmosis; true batch; energy efficiency; energy savings; system design
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/122633
DOI of Published Version
https://wc.idadesal.org/
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.