Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. The GlueX beamline and detector

The GlueX beamline and detector

Thumbnail Image
Download
Name

2005.14272.pdf

Description
Accepted version
Size

8.05 MB

Format

Adobe PDF

Checksum (MD5)

8492c7f15732125a18014795271d0a21

sword-2020-11-18T15:39:18.original.xml (130 B)
Original SWORD entry document
Author(s)
Hardin, John Melvin
•
Williams, Michael
Date Issued
2021
Journal
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Publisher
Elsevier BV
Version
Author's final manuscript
Abstract
© 2020 The GLUEX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 μs. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GLUEX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Terms of Use
Creative Commons Attribution-NonCommercial-NoDerivs License
http://creativecommons.org/licenses/by-nc-nd/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/135535
DOI of Published Version
10.1016/j.nima.2020.164807
https://doi.org/10.1016/j.nima.2020.164807
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.