Charging of miniature flat heat pipes
Name
231_2018_2366_ReferencePDF.pdf
Size
481.41 KB
Format
Adobe PDF
Checksum (MD5)
b3ffcd5d211dc20a06544f1b00c68036
Author(s) • • • •
Somasundaram, Sivanand
Bin, He
Mengyao, Wei
Tan, Chuan S
Wang, Evelyn N
Date Issued
April 28, 2018
Publisher
Springer Berlin Heidelberg
Version
Author's final manuscript
Abstract
Abstract
Accurate charging of vapor chambers is critical for deriving maximum performance. In this work methods and processes to improve the evacuation and back fill technique of charging miniature vapor are described and demonstrated. A burette based charging method for charging volumes of 10 to 200 μl is described. The charging station calibrations results are discussed. The main advantages realized in the system described are better accuracy or resolution up to 2 μl, reusability of same samples for multiple filling ratios and finally a simpler process to facilitate ease of use.