Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. On Unlimited Sampling and Reconstruction

On Unlimited Sampling and Reconstruction

Thumbnail Image
Download
Name

1905.03901.pdf

Description
Submitted version
Size

5.57 MB

Format

Adobe PDF

Checksum (MD5)

6b408e59075067812a4ed1ee4f0596cc

sword-2021-07-01T16:36:32.original.xml (130 B)
Original SWORD entry document
Author(s)
Bhandari, Ayush
•
Krahmer, Felix
•
Raskar, Ramesh
Date Issued
2020
Journal
IEEE Transactions on Signal Processing
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Version
Original manuscript
Abstract
IEEE Shannon's sampling theorem is one of the cornerstone topics that is well understood and explored, both mathematically and algorithmically. That said, practical realization of this theorem still suffers from a severe bottleneck due to the fundamental assumption that the samples can span an arbitrary range of amplitudes. In practice, the theorem is realized using so-called analog--to--digital converters (ADCs) which clip or saturate whenever the signal amplitude exceeds the maximum recordable ADC voltage thus leading to a significant information loss. In this paper, we develop an alternative paradigm for sensing and recovery, called the Unlimited Sampling Framework. It is based on the observation that when a signal is mapped to an appropriate bounded interval via a modulo operation before entering the ADC, the saturation problem no longer exists, but one rather encounters a different type of information loss due to the modulo operation. Such an alternative setup can be implemented, for example, via so-called folding or self-reset ADCs, as they have been proposed in various contexts in the circuit design literature. The key task that we need to accomplish in order to cope with this new type of information loss is to recover a bandlimited signal from its modulo samples. In this paper we derive conditions when perfect recovery is possible and complement them with a stable recovery algorithm. The sampling density required to guarantee recovery is independent of the maximum recordable ADC voltage and depends on the signal bandwidth only. Our recovery guarantees extend to measurements affected by bounded noise, which includes the case of round-off quantization. Numerical experiments validate our approach. For example, it is possible to recover functions with amplitudes orders of magnitude higher than the ADC's threshold from quantized modulo samples upto the unavoidable quantization error. Applications of the unlimited sampling paradigm can be found in a number of fields such as signal processing, communication and imaging.
MIT Department
Massachusetts Institute of Technology. Media Laboratory
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/134026
DOI of Published Version
https://doi.org/10.1109/TSP.2020.3041955
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.