Commissioning and performance of the CMS pixel tracker with cosmic ray muons
Name
0911.5434.pdf
Description
Submitted version
Size
3.12 MB
Format
Adobe PDF
Checksum (MD5)
4fa17d6cc5a5cd6fa9f3c2cb8fcb25b9
Author(s) • • • • • • • • •
Alver, Burak Han
Bauer, Gerry P
Bendavid, Joshua L.
Busza, Wit
Butz, Erik M.
Cali, Ivan Amos
Chan, M.
D'Enterria, David
Everaerts, Pieter Bruno Bart
Gomez-Ceballos, Guillelmo
Date Issued
March 2010
Journal
Journal of Instrumentation
Publisher
IOP Publishing
Citation
Chatrchyan, S. et al. "Commissioning and performance of the CMS pixel tracker with cosmic ray muons." Journal of Instrumentation 5 (March 2010): T03007 © 2010 IOP Publishing Ltd and SISSA
Version
Original manuscript
Abstract
The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.
MIT Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Massachusetts Institute of Technology. Laboratory for Nuclear Science
Massachusetts Institute of Technology. Department of Physics
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1088/1748-0221/5/03/T03007