Flexible Water Hose Failures: A Case Study and General Design Considerations
Name
11668_2016_91_ReferencePDF.pdf
Size
903.55 KB
Format
Adobe PDF
Checksum (MD5)
6f580be72411d6b2e346f37c2ee4b8f2
Author(s) •
Taylor, Richard
Eagar, Thomas W.
Date Issued
March 2016
Journal
Journal of Failure Analysis and Prevention
Publisher
Springer-Verlag
Citation
Taylor, Richard, and Thomas Eagar. “Flexible Water Hose Failures: A Case Study and General Design Considerations.” Journal of Failure Analysis and Prevention 16, no. 3 (March 16, 2016): 333–336.
Version
Author's final manuscript
Abstract
Flexible water hoses (or flexible hose connectors) have become commonplace in recent years and provide a low-cost and convenient alternative to rigid pipe. Unfortunately, inadequate designs, particularly with regard to the selection of materials and material parameters, have made some hoses prone to failure. Such failures are often initiated by incidental exposure to corrosive substances commonly found in homes (including chlorides in tap water) that attack and corrode the stainless steel metal braid. A failure of the braid then leads to a rupture of the water-carrying tube. We evaluate the design considerations pertinent to flexible water hose failures and consider a recent failure scenario that illustrates some key points.
MIT Department
Massachusetts Institute of Technology. Department of Materials Science and Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1007/s11668-016-0091-4