Motion-Tolerant Magnetic Earring Sensor and Wireless Earpiece for Wearable Photoplethysmography
Name
Ming-Zher-2010-Motion-Tolerant Magnetic Earring Sensor and Wireless Earpiece for Wearable Photoplethysmography.pdf
Size
697.3 KB
Format
Adobe PDF
Checksum (MD5)
cf0070ac553c02e08e5f7f6d867c8535
Author(s) • •
Poh, Ming-Zher
Swenson, Nicholas C.
Picard, Rosalind W.
Date Issued
June 2010
Journal
IEEE Transactions on Information Technology in Biomedicine
Publisher
Institute of Electrical and Electronics Engineers
Citation
Ming-Zher Poh, N.C. Swenson, and R.W. Picard. “Motion-Tolerant Magnetic Earring Sensor and Wireless Earpiece for Wearable Photoplethysmography.” Information Technology in Biomedicine, IEEE Transactions on 14.3 (2010): 786-794. © Copyright 2010 IEEE
Version
Final published version
Abstract
This paper addresses the design considerations and critical evaluation of a novel embodiment for wearable photoplethysmography (PPG) comprising a magnetic earring sensor and wireless earpiece. The miniaturized sensor can be worn comfortably on the earlobe and contains an embedded accelerometer to provide motion reference for adaptive noise cancellation. The compact wireless earpiece provides analog signal conditioning and acts as a data-forwarding device via a radio frequency transceiver. Using Bland-Altman and correlation analysis, we evaluated the performance of the proposed system against an FDA-approved ECG measurement device during daily activities. The mean ?? standard deviation (SD) of the differences between heart rate measurements from the proposed device and ECG (expressed as percentage of the average between the two techniques) along with the 95% limits of agreement (LOA = ??1.96 SD) was 0.62% ?? 4.51% (LOA = -8.23% and 9.46%), -0.49% ?? 8.65% (-17.39% and 16.42%), and -0.32% ?? 10.63% (-21.15% and 20.52%) during standing, walking, and running, respectively. Linear regression indicated a high correlation between the two measurements across the three evaluated conditions (r = 0.97, 0.82, and 0.76, respectively with p < 0.001). The new earring PPG system provides a platform for comfortable, robust, unobtrusive, and discreet monitoring of cardiovascular function.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Department of Biological Engineering
Massachusetts Institute of Technology. Media Laboratory
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1109/TITB.2010.2042607