Flow-Through Comb Electroporation Device for Delivery of Macromolecules
Name
Jensen_Flow-through.pdf
Size
2.32 MB
Format
Adobe PDF
Checksum (MD5)
c0f62941aa0e16f7cd8685232db8ee20
Author(s) • • •
Adamo, Andrea
Arione, Alessandro
Sharei, Armon Reza
Jensen, Klavs F
Date Issued
December 2012
Journal
Analytical Chemistry
Publisher
American Chemical Society (ACS)
Citation
Adamo, Andrea, Alessandro Arione, Armon Sharei, and Klavs F. Jensen. “Flow-Through Comb Electroporation Device for Delivery of Macromolecules.” Analytical Chemistry 85, no. 3 (February 5, 2013): 1637–1641.
Version
Author's final manuscript
Abstract
We present a microfluidic electroporation device with a comb electrode layout fabricated in polydimethylsiloxane (PMDS) and glass. Characterization experiments with HeLa cells and fluorescent dextran show efficient delivery (~95%) with low toxicity (cell viability ~85%) as well as rapid pore closure after electroporation. The activity of delivered molecules is also verified by silencing RNA (siRNA) studies that demonstrate gene knockdown in GFP expressing cells. This simple, scalable approach to microfluidic, flow-through electroporation could facilitate the integration of electroporation modules within cell analysis devices that perform multiple operations.
MIT Department
Massachusetts Institute of Technology. Department of Chemical Engineering
Koch Institute for Integrative Cancer Research at MIT
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1021/ac302887a