Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Intensity normalization of two-photon microscopy images for liver fibrosis analysis

Intensity normalization of two-photon microscopy images for liver fibrosis analysis

Thumbnail Image
Download
Name

79030P.pdf

Size

2.32 MB

Format

Adobe PDF

Checksum (MD5)

e5d8496e044154816225074bbcdeb1a1

Download all files submitted through automated deposit
sword-2019-01-03.original.zip (2.31 MB)
Author(s)
Singh, Vijay Raj
•
Rajapakse, Jagath C.
•
Yu, Hanry
•
So, Peter T. C.
Date Issued
February 2011
Journal
Proceedings Volume 7903, Multiphoton Microscopy in the Biomedical Sciences XI
Publisher
SPIE
Citation
Singh, Vijay Raj, Jagath C. Rajapakse, Hanry Yu, and Peter T. C. So. “Intensity Normalization of Two-Photon Microscopy Images for Liver Fibrosis Analysis.” Proceedings Volume 7903, 22-27 January, 2011, San Francisco, California, USA, edited by Ammasi Periasamy, Karsten König, and Peter T. C. So, SPIE, 2011. © 2011 SPIE.
Version
Final published version
Abstract
This paper presents an intensity normalization method for analysis of liver tissue images, acquired using the two-photon microscopy system at different stages of fibrosis. Image informatics methods require precise intensity segmentation for analysis of collagen, vessel and cellular structures. Intensities of the images recorded at different time intervals corresponding to the progression of fibrosis could vary spatially and temporally depending on the experimental conditions. These variations significantly affect the image segmentation process and thus the final image analysis, especially when automatic computer-based methods are used for diagnostic parameters quantification. We propose an adaptive intensity normalization method that facilitates spatial and temporal intensity variations of the images before the segmentation process. The images are first portioned into a tessellation of regions with relatively uniform background pixels intensities and then the normalization is performed to make sure the intensity range is unified throughout the whole set of image data. This approach is further extended for montage of images acquired from multianode photomultiplier tube based multifocal multiphoton microscope (MMM) system. The proposed approach significantly improves the automated analysis of images with varying intensities without any user intervention.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/120485
DOI of Published Version
https://doi.org/10.1117/12.876246
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.