Design of a Multi-Degree-of-Freedom Traction and Stabilization Device for Open Reduction and Internal Fixation of Distal Radius Fractures

Thumbnail Image
Download
Name

v001t13a007-dmd2021-1047.pdf

Description
Published version
Size

1.42 MB

Format

Adobe PDF

Checksum (MD5)

88eabe7f81bbc1a2decdbe75777d1e2b

sword-2022-01-24T18:35:09.original.xml (130 B)
Original SWORD entry document
Author(s)
Oeding, J
•
Bockman, S
•
Chiu, H
•
Hua, C
•
Connor, J
•
Slocum, A
Date Issued
2021
Journal
2021 Design of Medical Devices Conference
Publisher
ASME International
Citation
Oeding, J, Bockman, S, Chiu, H, Hua, C, Connor, J et al. 2021. "Design of a Multi-Degree-of-Freedom Traction and Stabilization Device for Open Reduction and Internal Fixation of Distal Radius Fractures." 2021 Design of Medical Devices Conference.
Version
Final published version
Abstract
Abstract
Open reduction and internal fixation (ORIF) is a surgical procedure performed with the objectives of restoring normal alignment and providing stability to broken bone fragments after a fracture. This procedure is increasingly used to treat fractures of the distal end of the radius. Reduction of the fracture into correct alignment is often achieved by the surgeon pulling and manipulating the hand while looking at real-time x-rays, and frequently requires large forces to distract impacted fragments from proximal bone. This can make the task of simultaneously aligning the fracture fragments and placing hardware to secure fragments into the correct position particularly challenging for surgeons. This study presents the design and preliminary testing of a multi-degree-of-freedom (DOF) device capable of performing both distraction and reduction of fractured bone fragments using a traction splint mechanism with locking joints that results in significantly reduced effort and greater accuracy in performing ORIF procedures on distal radius fractures. Quantitative force testing found an 80% reduction in the maximum force required to create needed traction, while qualitative tests with a hand surgeon found the device’s ability to reduce and stabilize bone fragments while hardware is secured to be more intuitive and less obstructive than existing techniques.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
https://hdl.handle.net/1721.1/139671
DOI of Published Version
https://doi.org/10.1115/DMD2021-1047
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.