  4. A unified relationship between bubble departure frequency and diameter during saturated nucleate pool boiling

A unified relationship between bubble departure frequency and diameter during saturated nucleate pool boiling

Thumbnail Image
Download
Name

A unified relationship between bubble departure frequency and diameter during saturated nucleate pool boiling.pdf

Description
Accepted version
Size

804.1 KB

Format

Adobe PDF

Checksum (MD5)

9dd6570b1c304042785e0054d4d5b191

sword-2022-04-25T15:01:01.original.xml (130 B)
Original SWORD entry document
Author(s)
Zhang, Lenan
•
Gong, Shuai
•
Lu, Zhengmao
•
Cheng, Ping
•
Wang, Evelyn N
Date Issued
2021
Journal
International Journal of Heat and Mass Transfer
Publisher
Elsevier BV
Citation
Zhang, Lenan, Gong, Shuai, Lu, Zhengmao, Cheng, Ping and Wang, Evelyn N. 2021. "A unified relationship between bubble departure frequency and diameter during saturated nucleate pool boiling." International Journal of Heat and Mass Transfer, 165.
Version
Author's final manuscript
Abstract
© 2020 The relationship between bubble departure frequency and diameter is fundamental to the boiling process and needs to be fully understood for prediction of overall boiling heat transfer performance. Hydrodynamic models for bubble departure were developed in previous studies. However, these models could not explain the dependence of bubble frequency on properties of the heating substrate and surrounding liquid, which was observed in many experiments. In this work, we develop a unified bubble departure theory for saturated nucleate pool boiling. The heat transfer in the bubble base region after bubble departure is taken into consideration. Two characteristic timescales, representing two dominant heat transfer processes for different regimes of bubble sizes, are extracted. These timescales, which depend on substrate and liquid properties, are used to determine bubble departure frequency. The results from our theory show reasonably good agreement with existing experimental data. The proposed model provides a unified relationship between bubble departure frequency and diameter for various combinations of heating substrates and working fluids in the saturated nucleate pool boiling regime.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-NonCommercial-NoDerivs License
http://creativecommons.org/licenses/by-nc-nd/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/142048
DOI of Published Version
https://doi.org/10.1016/J.IJHEATMASSTRANSFER.2020.120640
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.