Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems

Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems

Thumbnail Image
Download
Name

Fujimoto_Reproducibility of.pdf

Size

550.62 KB

Format

Adobe PDF

Checksum (MD5)

e4a1814f46bb9593638afe26a1f63259

Author(s)
Branchini, Lauren
•
Regatieri, Caio V.
•
Flores-Moreno, Ignacio
•
Baumann, Bernhard
•
Fujimoto, James G.
•
Duker, Jay S.
Date Issued
September 2011
Journal
Ophthalmology
Publisher
Elsevier
Citation
Branchini, Lauren, Caio V. Regatieri, Ignacio Flores-Moreno, Bernhard Baumann, James G. Fujimoto, and Jay S. Duker. “Reproducibility of Choroidal Thickness Measurements Across Three Spectral Domain Optical Coherence Tomography Systems.” Ophthalmology 119, no. 1 (January 2012): 119–123.
Version
Author's final manuscript
Abstract
Purpose To investigate the reproducibility of choroidal thickness measurements in normal subjects on 3 spectral domain optical coherence tomography (SD-OCT) instruments: Zeiss Cirrus HD-OCT (Carl Zeiss Meditec Inc., Dublin, CA), Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany), and Optovue RTVue (Optovue Inc., Fremont, CA). Design Cross-sectional non-interventional study. Participants Images were obtained in 28 eyes of 28 healthy undilated volunteers without ocular pathology in a clinical setting. Methods All subjects were imaged on the fovea using Cirrus HD 1-line raster, Spectralis enhanced depth imaging (EDI), and RTVue retina-cross. Main Outcome Measures The choroid was measured subfoveally, 750 μm temporal, and 750 μm nasal to the fovea. All measurements were performed by 2 independent observers. Two-way analysis of variance (ANOVA) with Bonferroni's post-test, Pearson correlation, and Bland–Altman analysis were used to compare measurements. Results The group of 28 subjects consisted of 7 men and 21 women, with an average age of 35.2 years (range, 23–64 years). A 2-way ANOVA with Bonferroni's post-test revealed no significant difference in the average subfoveal choroidal thickness (P > 0.05) among systems for any location: subfoveally, 750 μm temporal, and 750 μm nasal to the fovea. The measurements of choroidal thickness from any pair of 3 instruments (Cirrus vs. Spectralis, Cirrus vs. RTVue, Spectralis vs. RTVue) were also strongly correlated. The Pearson correlation among all 2 system pairs of the 3 systems was greater than 0.9 (P < 0.0001). The 95% limits of agreement among 4 choroidal thickness measurements were +11.21% to −13.57% (bias −1.17) between Cirrus and RTVue, +10.85% to −12.45% (bias −0.80) between Spectralis and RTVue, and +12.81% to −13.33% (bias −0.25) between Cirrus and Spectralis. Conclusions In our population of young healthy adults with normal vision, there was good reproducibility among choroidal thickness measurements of images acquired with Cirrus, Spectralis, and RTVue.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Creative Commons Attribution
http://creativecommons.org/licenses/by-nc-nd/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/100253
DOI of Published Version
https://doi.org/10.1016/j.ophtha.2011.07.002
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.