Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Inferring Aerosol Sources from Low-Cost Air Quality Sensor Measurements: A Case Study in Delhi, India

Inferring Aerosol Sources from Low-Cost Air Quality Sensor Measurements: A Case Study in Delhi, India

Thumbnail Image
Download
Name

acs.estlett.9b00393.pdf

Description
Published version
Size

2.19 MB

Format

Adobe PDF

Checksum (MD5)

8d025d244f8631dc1c20fdc066840cd0

sword-2019-09-20T13:43:17.original.xml (130 B)
Original SWORD entry document
Author(s)
Hagan, David Henry
•
Gani, Shahzad
•
Bhandari, Sahil
•
Patel, Kanan
•
Habib, Gazala
•
Apte, Joshua S.
•
Hildebrandt Ruiz, Lea
•
Kroll, Jesse
Date Issued
July 2019
Journal
Environment Science & Technology Letters
Publisher
American Chemical Society (ACS)
Citation
Hagan, David H. et al. "Inferring Aerosol Sources from Low-Cost Air Quality Sensor Measurements: A Case Study in Delhi, India." Environment Science & Technology Letters 6, 8 (July 2019): 467-472 © 2019 American Chemical Society
Version
Final published version
Abstract
Low-cost sensors (LCS) offer the opportunity to measure urban air quality at a spatiotemporal scale that is finer than what is currently practical with expensive research- or regulatory-grade instruments. Recently, the LCS research community has focused largely on sensor calibration, pollution monitoring, and exposure assessment; here, we investigate the applicability of LCS for characterizing particulate pollution sources in an urban environment. Using an integrated multipollutant LCS system (which measures both gases and particles), we collected air quality data for 6 weeks during the winter at a site in Delhi, India. The results were compared to measurements taken by co-located research-grade particle instruments. Non-negative matrix factorization was used to deconvolve LCS data into unique factors that were then identified by examining the factor composition and comparing them to the research-grade measurements. The data were described well by three factors: a combustion factor characterized by high CO levels and two factors characterized by measured particles. These factors align well with measurements by research-grade instruments, including particle types determined from factor analysis of online particle composition measurements. This work demonstrates that multipollutant LCS measurements, despite their inherent limitations (e.g., calibration challenges and inability to measure smallest particles), can provide insight into sources of fine particulate matter in a complex urban environment.
MIT Department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Massachusetts Institute of Technology. Department of Chemical Engineering
Terms of Use
Creative Commons Attribution-NonCommercial-NoDerivs License
http://creativecommons.org/licenses/by-nc-nd/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/122279
DOI of Published Version
https://doi.org/10.1021/acs.estlett.9b00393
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.