Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Size-optimized 32-channel brain arrays for 3 T pediatric imaging

Size-optimized 32-channel brain arrays for 3 T pediatric imaging

Thumbnail Image
Download
Name

Kanwisher-2011-Channel Brain Arrays for 3 T Pediatric Imaging.pdf

Size

2.58 MB

Format

Adobe PDF

Checksum (MD5)

298fe4bd51fffca861fe594615335c52

Author(s)
Keil, Boris
•
Alagappan, Vijay
•
Mareyam, Azma
•
McNab, Jennifer A.
•
Fujimoto, Kyoko
•
Tountcheva, Venata
•
Triantafyllou, Christina
•
Dilks, Daniel D.
•
Kanwisher, Nancy
•
Lin, Weili
more
Date Issued
December 2011
Journal
Magnetic Resonance in Medicine
Publisher
Wiley-Blackwell Pubishers
Citation
Keil, Boris et al. “Size-optimized 32-channel Brain Arrays for 3 T Pediatric Imaging.” Magnetic Resonance in Medicine 66.6 (2011): 1777–1787. Web.
Version
Author's final manuscript
Abstract
Size-optimized 32-channel receive array coils were developed for five age groups, neonates, 6 months old, 1 year old, 4 years old, and 7 years old, and evaluated for pediatric brain imaging. The array consisted of overlapping circular surface coils laid out on a close-fitting coil-former. The two-section coil former design was obtained from surface contours of aligned three-dimensional MRI scans of each age group. Signal-to-noise ratio and noise amplification for parallel imaging were evaluated and compared to two coils routinely used for pediatric brain imaging; a commercially available 32-channel adult head coil and a pediatric-sized birdcage coil. Phantom measurements using the neonate, 6-month-old, 1-year-old, 4-year-old, and 7-year-old coils showed signal-to-noise ratio increases at all locations within the brain over the comparison coils. Within the brain cortex the five dedicated pediatric arrays increased signal-to-noise ratio by up to 3.6-, 3.0-, 2.6-, 2.3-, and 1.7-fold, respectively, compared to the 32-channel adult coil, as well as improved G-factor maps for accelerated imaging. This study suggests that a size-tailored approach can provide significant sensitivity gains for accelerated and unaccelerated pediatric brain imaging.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences
McGovern Institute for Brain Research at MIT
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike 3.0
http://creativecommons.org/licenses/by-nc-sa/3.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/71156
DOI of Published Version
https://doi.org/10.1002/mrm.22961
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.