This is not the latest version of this item. The latest version can be found here.
A Wide-Range, Wireless Wearable Inertial Motion Sensing System for Capturing Fast Athletic Biomechanics in Overhead Pitching
Name
sensors-19-03637.pdf
Description
Published version
Size
2.54 MB
Format
Adobe PDF
Checksum (MD5)
1c97e3fc2b1ef6e378e52f2576e5201b
Author(s) • • • • • •
Lapinski, Michael
Brum Medeiros, Carolina
Moxley Scarborough, Donna
Berkson, Eric
Gill, Thomas J
Kepple, Thomas
Paradiso, Joseph A
Date Issued
2019
Journal
Sensors
Publisher
MDPI AG
Version
Final published version
Abstract
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. The standard technology used to capture motion for biomechanical analysis in sports has employed marker-based optical systems. While these systems are excellent at providing positional information, they suffer from a limited ability to accurately provide fundamental quantities such as velocity and acceleration (hence forces and torques) during high-speed motion typical of many sports. Conventional optical systems require considerable setup time, can exhibit sensitivity to extraneous light, and generally sample too slowly to accurately capture extreme bursts of athletic activity. In recent years, wireless wearable sensors have begun to penetrate devices used in sports performance assessment, offering potential solutions to these limitations. This article, after determining pressing problems in sports that such sensors could solve and surveying the state-of-the-art in wearable motion capture for sports, presents a wearable dual-range inertial and magnetic sensor platform that we developed to enable an end-to-end investigation of high-level, very wide dynamic-range biomechanical parameters. We tested our system on collegiate and elite baseball pitchers, and have derived and measured metrics to glean insight into performance-relevant motion. As this was, we believe, the first ultra-wide-range wireless multipoint and multimodal inertial and magnetic sensor array to be used on elite baseball pitchers, we trace its development, present some of our results, and discuss limitations in accuracy from factors such as soft-tissue artifacts encountered with extreme motion. In addition, we discuss new metric opportunities brought by our systems that may be relevant for the assessment of micro-trauma in baseball.
Terms of Use
Creative Commons Attribution 4.0 International license
Persistent DSpace Link
DOI of Published Version
10.3390/s19173637