Single-step quantitative susceptibility mapping with variational penalties: Single-Step Qsm with Variational Penalties
Name
nihms803484.pdf
Description
Accepted version
Size
2.1 MB
Format
Adobe PDF
Checksum (MD5)
015311b79587b88a0bb1abcf4828e767
Author(s) • • • • • • • • •
Chatnuntawech, Itthi
McDaniel, Patrick
Cauley, Stephen F
Gagoski, Borjan A
Langkammer, Christian
Martin, Adrian
Grant, P Ellen
Wald, Lawrence L
Setsompop, Kawin
Adalsteinsson, Elfar
Date Issued
2017
Journal
NMR in Biomedicine
Publisher
Wiley
Citation
Chatnuntawech, Itthi, et al. "Single-Step Quantitative Susceptibility Mapping with Variational Penalties." Nmr in Biomedicine 30 4 (2017).
Version
Author's final manuscript
Abstract
Copyright © 2016 John Wiley & Sons, Ltd. Quantitative susceptibility mapping (QSM) estimates the underlying tissue magnetic susceptibility from the gradient echo (GRE) phase signal through background phase removal and dipole inversion steps. Each of these steps typically requires the solution of an ill-posed inverse problem and thus necessitates additional regularization. Recently developed single-step QSM algorithms directly relate the unprocessed GRE phase to the unknown susceptibility distribution, thereby requiring the solution of a single inverse problem. In this work, we show that such a holistic approach provides susceptibility estimation with artifact mitigation and develop efficient algorithms that involve simple analytical solutions for all of the optimization steps. Our methods employ total variation (TV) and total generalized variation (TGV) to jointly perform the background removal and dipole inversion in a single step. Using multiple spherical mean value (SMV) kernels of varying radii permits high-fidelity background removal whilst retaining the phase information in the cortex. Using numerical simulations, we demonstrate that the proposed single-step methods reduce the reconstruction error by up to 66% relative to the multi-step methods that involve SMV background filtering with the same number of SMV kernels, followed by TV- or TGV-regularized dipole inversion. In vivo single-step experiments demonstrate a dramatic reduction in dipole streaking artifacts and improved homogeneity of image contrast. These acquisitions employ the rapid three-dimensional echo planar imaging (3D EPI) and Wave-CAIPI (controlled aliasing in parallel imaging) trajectories for signal-to-noise ratio-efficient whole-brain imaging. Herein, we also demonstrate the multi-echo capability of the Wave-CAIPI sequence for the first time, and introduce an automated, phase-sensitive coil sensitivity estimation scheme based on a 4-s calibration acquisition. Copyright © 2016 John Wiley & Sons, Ltd.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Harvard University--MIT Division of Health Sciences and Technology
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1002/NBM.3570