Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Detectability of cerebellar activity with magnetoencephalography and electroencephalography

Detectability of cerebellar activity with magnetoencephalography and electroencephalography

Thumbnail Image
Download
Name

hbm.24951.pdf

Description
Published version
Size

7.31 MB

Format

Adobe PDF

Checksum (MD5)

6a2a45f9d2117f14d0dcca7d1cb38f95

sword-2022-03-17T15:08:39.original.xml (130 B)
Original SWORD entry document
Author(s)
Samuelsson, JG
•
Sundaram, P
•
Khan, S
•
Sereno, MI
•
Hämäläinen, MS
Date Issued
June 15, 2020
Journal
Human Brain Mapping
Publisher
Wiley
Citation
Samuelsson, JG, Sundaram, P, Khan, S, Sereno, MI and Hämäläinen, MS. 2020. "Detectability of cerebellar activity with magnetoencephalography and electroencephalography." Human Brain Mapping, 41 (9).
Version
Final published version
Abstract
© 2020 The Authors. Human Brain Mapping published by Wiley Periodicals, Inc. Electrophysiological signals from the cerebellum have traditionally been viewed as inaccessible to magnetoencephalography (MEG) and electroencephalography (EEG). Here, we challenge this position by investigating the ability of MEG and EEG to detect cerebellar activity using a model that employs a high-resolution tessellation of the cerebellar cortex. The tessellation was constructed from repetitive high-field (9.4T) structural magnetic resonance imaging (MRI) of an ex vivo human cerebellum. A boundary-element forward model was then used to simulate the M/EEG signals resulting from neural activity in the cerebellar cortex. Despite significant signal cancelation due to the highly convoluted cerebellar cortex, we found that the cerebellar signal was on average only 30–60% weaker than the cortical signal. We also made detailed M/EEG sensitivity maps and found that MEG and EEG have highly complementary sensitivity distributions over the cerebellar cortex. Based on previous fMRI studies combined with our M/EEG sensitivity maps, we discuss experimental paradigms that are likely to offer high M/EEG sensitivity to cerebellar activity. Taken together, these results show that cerebellar activity should be clearly detectable by current M/EEG systems with an appropriate experimental setup.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Terms of Use
Creative Commons Attribution 4.0 International license
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/141258
DOI of Published Version
10.1002/hbm.24951
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.