  5. Development and analysis of high-frequency, high-density PFC power conversion

Development and analysis of high-frequency, high-density PFC power conversion

Thumbnail Image
Download
Name

965198141-MIT.pdf

Description
Full printable version
Size

15.57 MB

Format

Adobe PDF

Checksum (MD5)

19909ede01b5d8bbffe3127f63919777

Author(s)
AlShehab, Ali Saeed
Advisor(s)
David J. Perreault.
Date Issued
2015
Publisher
Massachusetts Institute of Technology
Abstract
This thesis explores the design of power converters that deliver isolated low-voltage dc output (~24V) and operate from "universal" ac input voltage (85 - 264 Vac RMS). It is important that these converters have good overall efficiency (~90-95%), and good ac line power factor (>0.9, and ideally >0.95) to better utilize the available energy. This thesis looks into achieving high efficiency, high power factor, low voltage stresses, and smaller component sizes by utilizing high frequency operation. The research focuses on component and subsystem evaluation, development and testing as a part of many-person research in this space. The thesis presents a literature based study on current PFC circuit designs and tradeoffs. It also introduces a specific PFC architecture, which provides a low dc output voltage drawing energy from a wide range ac input voltage while maintaining a high power factor. The architecture includes two stages: The first is a "Power Factor Correction" (PFC) which functions as an input stage drawing energy from a wide-range input current. It uses a resonant transition inverted (RTI) buck converter topology to step down the voltage from line voltage (85 - 264 Vac RMS) to around 72V. Furthermore, the inductor for the RTI buck is analyzed. The middle stage is an energy buffer to provide the required energy level for twice line frequency energy buffering and 20ms of energy hold up. The capacitor requirements, analysis, and selection are explored and developed. The second stage is a transformation and regulation stage which also provides electrical isolation between the ac input and dc output. The thesis also explores the use of available conventional high-density telecom "brick" converters as a second stage. In conclusion, the project explores the possibility of using a buck configuration for the PFC, sacrificing the ability to use high energy density 400V capacitors while gaining the advantage of using the high-density telecom brick converters and different output voltage options.
Description
Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2015.
Cataloged from PDF version of thesis. "September 2015."
Includes bibliographical references (pages 83-85).
Subjects
Electrical Engineering and Computer Science.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.