Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Experimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchanger

Experimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchanger

Thumbnail Image
Download
Name

13369_2014_1384_ReferencePDF.pdf

Size

799.87 KB

Format

Adobe PDF

Checksum (MD5)

9db515a459a5f4c27ebd44f15267bb32

Download all files submitted through automated deposit
art_5900865857528623346.zip (744.27 KB)
Author(s)
Habib, M. A.
•
Said, S. A.
•
Khalifa, A.
•
Nemitallah, M. A.
•
Ayinde, T.
Date Issued
October 2014
Journal
Arabian Journal for Science and Engineering
Publisher
Springer Berlin Heidelberg
Citation
Habib, M. A., S. A. Said, A. Khalifa, M. A. Nemitallah, and T. Ayinde. “Experimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchanger.” Arabian Journal for Science and Engineering 39, no. 11 (October 4, 2014): 8187–8198.
Version
Author's final manuscript
Abstract
Flow maldistribution in heat exchanger tubes can significantly affect its performance. In this work, 16 tubes are connected between the inlet and the exit headers forming the heat exchanger. The feed nozzle is connected to the inlet header, and its connection point can be altered. The influences of inlet flow Reynolds number, nozzle diameter, number of nozzles and nozzle location on the flow maldistribution are experimentally investigated. Water is chosen to be the working fluid inside the heat exchanger set of tubes. At lower flow rates, the results showed that the flow Reynolds number has a significant effect on the flow maldistribution inside the heat exchanger set of tubes; however, at higher flow rates, this effect was insignificant. Locating the nozzle at the center of the inlet header resulted in about 25–30% reduction in the standard deviation (STD) of the flow rate inside the tubes. Increasing the number of inlet nozzles resulted in an insignificant effect on the flow maldistribution. Increasing the nozzle diameter resulted in increased STD of the flow rate distribution among the tubes and pressure drop across the tubes at the considered heat exchanger geometry and water flow rate.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/103147
DOI of Published Version
https://doi.org/10.1007/s13369-014-1384-0
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.