Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. AN RFQ DIRECT INJECTION SCHEME FOR THE ISODAR HIGH INTENSITY H+₂ CYCLOTRON

AN RFQ DIRECT INJECTION SCHEME FOR THE ISODAR HIGH INTENSITY H+₂ CYCLOTRON

Thumbnail Image
Download
Name

d27507ed0479980c3e5042a831258ab4aac2.pdf

Size

629.34 KB

Format

Adobe PDF

Checksum (MD5)

5f69b8b38a88d4af641f9fbb5dec6166

Download all files submitted through automated deposit
sword-2019-03-14.original.zip (532.54 KB)
Author(s)
Hamm, Robert
•
Winklehner, Daniel
•
Alonso, Jose Ramon
•
Conrad, Janet Marie
Date Issued
July 2015
Journal
Proceedings of IPAC2015
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Winklehner, D., R. Hamm, J. Alonso and J. Conrad. "An RFQ direct injection scheme for the isodar high intersity H+₂ cyclotron." In Proceedings of IPAC2015, Richmond, VA, July 26 2015, p. WEPTY048.
Version
Final published version
Abstract
IsoDAR is a novel experiment designed to measure neutrino oscillations through e disappearance, thus providing a definitive search for sterile neutrinos. In order to generate the necessary anti-neutrino flux, a high intensity primary proton beam is needed. In IsoDAR, H+2 is accelerated and is stripped into protons just before the target, to overcome space charge issues at injection. As part of the design, we have refined an old proposal to use an RFQ to axially inject bunched H+2 ions into the driver cyclotron. This method has several advantages over a classical low energy beam transport (LEBT) design: (1) The bunching efficiency is higher than for the previously considered two-gap buncher and thus the overall injection efficiency is higher. This relaxes the constraints on the H+2 current required from the ion source. (2) The overall length of the LEBT can be reduced. (3) The RFQ can also accelerate the ions. This enables the ion source platform high voltage to be reduced from 70 kV to 30 kV, making underground installation easier. We are presenting the preliminary RFQ design parameters and first beam dynamics simulations from the ion source to the spiral inflector entrance.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Massachusetts Institute of Technology. Laboratory for Nuclear Science
Terms of Use
Creative Commons Attribution 3.0 unported license
https://creativecommons.org/licenses/by/3.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/121004
DOI of Published Version
https://pdfs.semanticscholar.org/9453/d27507ed0479980c3e5042a831258ab4aac2.pdf?_ga=2.179299236.1484195457.1552570449-1608308357.1544797307
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.