Spatial distribution of dynamic amplification in progressive collapse analysis of building frames
Name
926708640-MIT.pdf
Description
Full printable version
Size
10.32 MB
Format
Adobe PDF
Checksum (MD5)
24d30a40c195c627374f8c9b537e4905
Author(s)
Yang, Zifan (Frank Zifan)
Advisor(s)
Pierre Ghisbain.
Date Issued
2015
Publisher
Massachusetts Institute of Technology
Abstract
The purpose to use Dynamic Application factor is to design and analysis the building and structures more efficient under the progressive collapse where one can only use only the Linear Static Analysis and times the results by the DAF instead of using more complex Linear Dynamic Analysis. It is suggested in the code that Dynamic Amplification Factor should be 2 to account for the all the dynamic effect, however, the simulation from this paper suggest otherwise. Throughout the four case analysis in this paper, none of them has more than half of the design members with qualified Dynamic Amplification Factor which suggests that the current code has failed to predict a efficient loading condition for one to analysis the building under the progressive collapse condition.
Description
Thesis: M. Eng., Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, 2015.
Cataloged from PDF version of thesis.
Includes bibliographical references (pages 61-64).
Subjects
Civil and Environmental Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Persistent DSpace Link