Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Transport and shear in a microfluidic membrane bilayer device for cell culture

Transport and shear in a microfluidic membrane bilayer device for cell culture

Thumbnail Image
Download
Name

Griffith_Transport Shear.pdf

Size

795.11 KB

Format

Adobe PDF

Checksum (MD5)

49caed69ea620bee4283671f5b08f560

Author(s)
Inamdar, Niraj K.
•
Griffith, Linda G.
•
Borenstein, Jeffrey T.
Date Issued
June 2011
Journal
Biomicrofluidics
Publisher
American Institute of Physics (AIP)
Citation
Inamdar, Niraj K., Linda G. Griffith, and Jeffrey T. Borenstein. “Transport and Shear in a Microfluidic Membrane Bilayer Device for Cell Culture.” Biomicrofluidics 5.2 (2011): 022213. © 2011 American Institute of Physics
Version
Final published version
Abstract
Microfluidic devices have been established as useful platforms for cell culture for a broad range of applications, but challenges associated with controlling gradients of oxygen and other soluble factors and hemodynamic shear forces in small, confined channels have emerged. For instance, simple microfluidic constructs comprising a single cell culture compartment in a dynamic flow condition must handle tradeoffs between sustaining oxygen delivery and limiting hemodynamic shear forces imparted to the cells. These tradeoffs present significant difficulties in the culture of mesenchymal stem cells (MSCs), where shear is known to regulate signaling, proliferation, and expression. Several approaches designed to shield cells in microfluidic devices from excessive shear while maintaining sufficient oxygen concentrations and transport have been reported. Here we present the relationship between oxygen transport and shear in a “membrane bilayer” microfluidic device, in which soluble factors are delivered to a cell population by means of flow through a proximate channel separated from the culture channel by a membrane. We present an analytical model that describes the characteristics of this device and its ability to independently modulate oxygen delivery and hemodynamic shear imparted to the cultured cells. This bilayer configuration provides a more uniform oxygen concentration profile that is possible in a single-channel system, and it enables independent tuning of oxygen transport and shear parameters to meet requirements for MSCs and other cells known to be sensitive to hemodynamic shear stresses.
MIT Department
Massachusetts Institute of Technology. Center for Biomedical Engineering
Massachusetts Institute of Technology. Department of Biological Engineering
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/75775
DOI of Published Version
https://doi.org/10.1063/1.3576925
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.