Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Libraries
  3. MIT Theses
  4. Doctoral Theses
  5. Engineering genetically-encodable MRI contrast agents for in vivo imaging

Engineering genetically-encodable MRI contrast agents for in vivo imaging

Thumbnail Image
Download
Name

890465963-MIT.pdf

Description
Full printable version
Size

9.4 MB

Format

Adobe PDF

Checksum (MD5)

41f081e250152ff4678ec4adff35bf0f

Author(s)
Matsumoto, Yuri, Ph. D. Massachusetts Institute of Technology
Advisor(s)
Alan P. Jasanoff.
Alternative Title
Engineering genetically-encodable magnetic resonance imaging contrast agents for in vivo imaging
Date Issued
2014
Publisher
Massachusetts Institute of Technology
Abstract
Magnetic resonance imaging (MRI) is gaining recognition as a powerful tool in biological research, offering non-invasive access to anatomy and activity at high spatial and temporal resolution. However, the range of biological phenomena accessible to measurement by MRI is limited, due to a current lack of molecular-level methods for detecting physiological processes in living organisms. One way to overcome this limitation is to develop contrast agents that report physiological events at a molecular level. Traditionally MRI contrast agents have been based on small molecules that chelate paramagnetic ions such as Gd (III), but synthesis and delivery of such exogenously applied agents are complicated. Genetically-encodable MRI sensors may overcome some of these issues. In this thesis, we describe new class of MRI contrast agents which will be broadly applicable as genetically-controlled tools for in vivo imaging. The major goal of my thesis research was to improve the sensitivity of the existing protein-based MRI contrast agent, ferritin (Ft) by inducing it to accumulate larger number of iron atoms per particle in a physiological environment. Using a high throughput genetic screening process, we obtained Ft mutants that show threefold greater cellular iron accumulation than mammalian heavy chain Ft. In another project, we used the engineered Ft to develop a dynamic gene reporter that responds to changes in gene expression levels in vivo via aggregation-dependent MRI contrast changes. Successful creation of genetically-encodable MRI contrast agents that are robust and sensitive enough to be applied in vivo will enable neuroscientists and biologists to study molecular processes of living subjects.
Description
Thesis: Ph. D., Massachusetts Institute of Technology, Department of Biological Engineering, 2014.
Cataloged from PDF version of thesis.
Includes bibliographical references (pages 129-150).
Subjects
Biological Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Biological Engineering
Terms of Use
MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/90677
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.