The bubbly-slug transition in a high velocity two phase flow
Name
HTL_TR_1964_029.pdf
Size
1.84 MB
Format
Adobe PDF
Checksum (MD5)
335a200c061e511fa5391978b185725f
Author(s) •
Griffith, P.
Snyder, George A.
Date Issued
1964
Publisher
Cambridge, Mass. : M.I.T. Division of Sponsored Research, [1964]
Series/Report no.
Technical report (Massachusetts Institute of Technology, Heat Transfer Laboratory) ; no. 29.
Abstract
A possible mechanism for the transition between bubbly and slug flow is proposed and tested in a simulated slug flow system. No sudden collapse of slug flow with increasing velocity is found and it is concluded that: a. Slug flow is generally stable at voids greater than 35%. b. Bubbly flow at voids higher than this is a result of entrance conditions. c. Visual observations of bubbly flow in unheated systems at higher voids are most likely faulty. No simple asymptote limit or criterion that would predict the location of the bubbly-slug transition was found.
Subjects
Bubbles.
Pipe -- Fluid dynamics.
Heat -- Transmission.
Persistent DSpace Link