Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Libraries
  3. MIT Theses
  4. Graduate Theses
  5. Enteric adenovirus and coliphage as microbial indicators in Singapore's Kallang Basin

Enteric adenovirus and coliphage as microbial indicators in Singapore's Kallang Basin

Thumbnail Image
Download
Name

890138359-MIT.pdf

Description
Full printable version
Size

6.78 MB

Format

Adobe PDF

Checksum (MD5)

13cfe055f2f2b95f5da646d756ccf9db

Author(s)
Liu, Tina Y
Advisor(s)
Peter Shanahan.
Date Issued
2014
Publisher
Massachusetts Institute of Technology
Abstract
E. coli, Enterococci, and other fecal indicator bacteria have been the gold standard for assessing and regulating water quality. However, the presence of these water quality indicators often do not reflect the presence of viral pathogens, such as human enteric viruses, posing significant health risks to the general population. Furthermore, high concentrations of E. coli are often found in tropical environments with no apparent source of fecal contamination. In order to gain comprehensive insight on the recreational water quality of Kallang Basin in Singapore, it is important to establish an understanding of the interactions between pathogens and other microorganisms within the environment. This study focuses on enteric adenovirus and coliphage (F' male-specific and somatic) as potential alternative indicators of fecal contamination. Adenovirus and coliphage concentrations from water samples collected over a 48-hour period were quantified using qPCR assay and cell culture methods, respectively, and analyzed for trends. The presence of viruses was compared to that of E. coli and Enterococci from the same samples. The results from this study suggest significant fecal contamination originating from the tributaries that flow into the Kallang Basin. E. coli and Enterococci concentrations at each station exceeded U.S. EPA regulation standards, however, neither correlated with the presence of adenovirus. Additionally, there was an overall trend of higher concentrations of microorganisms during the first 24-hours of sampling than the second, potentially due to rainfall prior to sampling. The findings from this study emphasize the need for further investigation of pathogenic microorganism to establish effective indices for recreational water quality monitoring in the Kallang Basin.
Description
Thesis: M. Eng., Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, 2014.
Cataloged from PDF version of thesis.
Includes bibliographical references (pages 36-38).
Subjects
Civil and Environmental Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/90024
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.