EFFECT OF FILTRATION AND PARTICULATE FOULING IN MEMBRANE DISTILLATION
Name
2-IDAWC_Warsinger The Effect Of Filtration And Particulate Fouling In Membrane Distillation.pdf
Size
2.78 MB
Format
Adobe PDF
Checksum (MD5)
8a979d3ecbafacac37610aaf1c9a0713
Author(s) • • • •
Warsinger, David Elan Martin
Swaminathan, Jaichander
Chung, Hyung Won
Jeong, Seongpil
Lienhard, John H
Date Issued
September 2015
Journal
Proceedings of the 2015 International Desalination Association World Congress on Desalination and Water Reuse
Publisher
International Desalination Association
Citation
Warsinger, David Martin, Jaichander Swaminathan, Hyung Won Chung, Seongpil Jeong, and John H. Lienhard V. "EFFECT OF FILTRATION AND PARTICULATE FOULING IN MEMBRANE DISTILLATION." 2015 International Desalination Association World Congress on Desalination and Water Reuse (September 2015).
Version
Author's final manuscript
Abstract
Fouling and scaling in membrane distillation (MD) is one of the significant barriers to its continued growth. Fouling in MD blocks the pores, causing a decline in permeate flux, and may eventually lead to wetting of a hydrophobic membrane by the saline feed, contaminating the permeate. Many previous studies on MD have observed that while MD is more fouling resistant than reverse osmosis (RO), inorganic salt precipitation on the membrane surface under supersaturated conditions may readily foul and cause wetting of the membranes. While most studies have assumed that crystal growth occurs directly on the membrane surface, precipitation of particles in the bulk which then migrate to the surface may play a significant or dominant role. In this study, membrane distillation experiments are run at varied supersaturated salinities with and without filtration in equivalent operating conditions to examine the effectiveness of particulate fouling in MD, and thus also the role of bulk precipitation in inorganic fouling. Conditions were designed to favor surface crystal growth over bulk nucleation, to examine the limiting case. The experiment is paired with heat and mass transfer and solubility numerical modeling to analyze the effects of concentration polarization to accurately calculate the saturation index (SI) in the bulk and at the membrane surface. The results show that the removal of particles precipitating in the bulk makes a tremendous difference in reducing flux decline, visible crystals on the membrane surface, and wetting. This implies that bulk nucleation followed by deposition, rather than surface crystal growth, dominates the scaling process in MD when the bulk is supersaturated.
MIT Department
Massachusetts Institute of Technology. Abdul Latif Jameel World Water & Food Security Lab
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
http://s23.a2zinc.net/clients/IDA/IDAWC15/Public/SessionDetails.aspx?FromPage=Sessions.aspx&SessionID=302&SessionDateID=5