Simulated plasma facing component measurements for an in situ surface diagnostic on Alcator C-Mod
Name
Whyte_Simulated Plasma.pdf
Size
537.6 KB
Format
Adobe PDF
Checksum (MD5)
ea9ade0da6db68725d3fdf6cde35e4e0
Author(s) •
Hartwig, Zachary Seth
Whyte, Dennis G
Date Issued
October 2010
Journal
Review of Scientific Instruments
Publisher
American Institute of Physics
Citation
Hartwig, Z. S., and D. G. Whyte. “Simulated plasma facing component measurements for an in situ surface diagnostic on Alcator C-Mod.” Review of Scientific Instruments 81 (2010): 10E106.© 2011 American Institute of Physics
Version
Final published version
Abstract
The ideal in situ plasma facing component (PFC) diagnostic for magnetic fusion devices would perform surface element and isotope composition measurements on a shot-to-shot ( ∼ 10 min) time scale with ∼ 1 μm depth and ∼ 1 cm spatial resolution over large areas of PFCs. To this end, the experimental adaptation of the customary laboratory surface diagnostic—nuclear scattering of MeV ions—to the Alcator C-Mod tokamak is being guided by ACRONYM, a Geant4 synthetic diagnostic. The diagnostic technique and ACRONYM are described, and synthetic measurements of film thickness for boron-coated PFCs are presented.
MIT Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Massachusetts Institute of Technology. Plasma Science and Fusion Center
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1063/1.3478634