Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. High Frequency Sampling of TTL Pulses on a Raspberry Pi for Diffuse Correlation Spectroscopy Applications

High Frequency Sampling of TTL Pulses on a Raspberry Pi for Diffuse Correlation Spectroscopy Applications

Thumbnail Image
Download
Name

Tivnan-2015-High Frequency Sampl.pdf

Size

1.39 MB

Format

Adobe PDF

Checksum (MD5)

fa123803bf849bb6528c733279b7c9ba

Author(s)
Tivnan, Matthew
•
Wolf, David
•
Vishwanath, Karthik
•
Gurjar, Rajan S.
Date Issued
August 2015
Journal
Sensors
Publisher
MDPI AG
Citation
Tivnan, Matthew, Rajan Gurjar, David Wolf, and Karthik Vishwanath. “High Frequency Sampling of TTL Pulses on a Raspberry Pi for Diffuse Correlation Spectroscopy Applications.” Sensors 15, no. 8 (August 2015): 19709–19722.
Version
Final published version
Abstract
Diffuse Correlation Spectroscopy (DCS) is a well-established optical technique that has been used for non-invasive measurement of blood flow in tissues. Instrumentation for DCS includes a correlation device that computes the temporal intensity autocorrelation of a coherent laser source after it has undergone diffuse scattering through a turbid medium. Typically, the signal acquisition and its autocorrelation are performed by a correlation board. These boards have dedicated hardware to acquire and compute intensity autocorrelations of rapidly varying input signal and usually are quite expensive. Here we show that a Raspberry Pi minicomputer can acquire and store a rapidly varying time-signal with high fidelity. We show that this signal collected by a Raspberry Pi device can be processed numerically to yield intensity autocorrelations well suited for DCS applications. DCS measurements made using the Raspberry Pi device were compared to those acquired using a commercial hardware autocorrelation board to investigate the stability, performance, and accuracy of the data acquired in controlled experiments. This paper represents a first step toward lowering the instrumentation cost of a DCS system and may offer the potential to make DCS become more widely used in biomedical applications.
MIT Department
Lincoln Laboratory
Terms of Use
Creative Commons Attribution
http://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/99677
DOI of Published Version
https://doi.org/10.3390/s150819709
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.