Feasibility study for a high-k temperature fluctuation diagnostic based on soft x-ray imaging
Name
5.0043819.pdf
Description
Published version
Size
6.08 MB
Format
Adobe PDF
Checksum (MD5)
d5e83799fab37cc09b15b822b708c919
Author(s) • • • • • • •
Chen, X
Ruiz, J Ruiz
Howard, NT
Guttenfelder, W
Candy, J
Hughes, JW
Granetz, RS
White, AE
Date Issued
2021
Journal
Review of Scientific Instruments
Publisher
AIP Publishing
Citation
Chen, X, Ruiz, J Ruiz, Howard, NT, Guttenfelder, W, Candy, J et al. 2021. "Feasibility study for a high-k temperature fluctuation diagnostic based on soft x-ray imaging." Review of Scientific Instruments, 92 (5).
Version
Final published version
Abstract
A new pseudolocal tomography algorithm is developed for soft X-ray(SXR) imaging measurements of the turbulent electron temperature fluctuations (δ Te) in tokamaks and stellarators. The algorithm overcomes the constraints of limited viewing ports on the vessel wall (viewing angle) and limited number of lines of sight (LOS). This is accomplished by increasing the number of LOS locally in a region of interest. Numerical modeling demonstrates that the wavenumber spectrum of the turbulence can be reliably reconstructed, with an acceptable number of viewing angles and LOS and suitable low SNR detectors. We conclude that a SXR imaging diagnostic for measurements of turbulent δ Te using a pseudolocal reconstruction algorithm is feasible.
MIT Department
Massachusetts Institute of Technology. Plasma Science and Fusion Center
Terms of Use
Creative Commons Attribution 4.0 International License
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1063/5.0043819