  4. Comparative assessment of the effects of 3D printed feed spacers on process performance in MD systems

Comparative assessment of the effects of 3D printed feed spacers on process performance in MD systems

Thumbnail Image
Download
Name

THOMAS 3D printed MD spacers Desalination 2021 preprint.pdf

Size

6.42 MB

Format

Adobe PDF

Checksum (MD5)

0b7ee9f607d5d743fc0ebc590bcc0865

Author(s)
Thomas, Navya
•
Swaminathan, Jaichander
•
Zaragoza, Guillermo
•
Abu Al-Rub, Rashid K.
•
Lienhard, John H
•
Arafat, Hassan A.
Date Issued
January 2021
Journal
Desalination
Publisher
Elsevier BV
Citation
Thomas, Navya et al. “Comparative assessment of the effect of 3D printed feed spacer geometries on process performance in membrane distillation systems.” Desalination 503 (May 2021): 114940 © 2021 Elsevier B.V.
Version
Author's final manuscript
Abstract
In this study, process enhancements achieved by the use of 3D printed feed spacers based on triply periodic minimal surfaces (TPMS) were comparatively assessed using the two most common membrane distillation (MD) configurations: air gap (AGMD) and direct contact (DCMD). The MD performance was assessed based on the impact of spacer design (TPMS vs. commercial spacer) on flux and feed channel pressure drop, and their consequent impact on the levelized cost of water (COW). The studied spacer architectures led to a minimal improvement (≤17%) in AGMD flux, much lower than that achieved in DCMD (≤57%). Consequently, for a waste heat-operated MD process, the spacer-induced channel pressure drop became the most influential cost bottleneck on COW. Generally, the contribution of the pumping cost to the total operating cost was found to be greater for DCMD than AGMD. Thus, the COW of a waste heat operated DCMD is more sensitive to a decrease in spacer-induced channel pressure drop than in an AGMD. For an MD process operated with additional heat cost, the flux improvement achieved using TPMS spacers reduces the thermal energy component of the operating cost. Ultimately, this predominantly contributes to a lower COW.
MIT Department
Rohsenow Kendall Heat Transfer Laboratory (Massachusetts Institute of Technology)
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/129639
DOI of Published Version
https://doi.org/10.1016/j.desal.2021.114940