Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Modeling Dynamic Ankle Mechanical Impedance in Relaxed Muscle

Modeling Dynamic Ankle Mechanical Impedance in Relaxed Muscle

Thumbnail Image
Download
Name

777_1.pdf

Size

531.92 KB

Format

Adobe PDF

Checksum (MD5)

7c772c8d6da97e055dad2f0590403f0c

Download all files submitted through automated deposit
sword-2018-11-30.original.zip (497.22 KB)
Author(s)
Lee, Hyunglae
•
Hogan, Neville
Date Issued
November 2011
Journal
ASME 2011 Dynamic Systems and Control Conference and Bath/ASME Symposium on Fluid Power and Motion Control, Volume 2
Publisher
ASME International
Citation
Lee, Hyunglae, and Neville Hogan. “Modeling Dynamic Ankle Mechanical Impedance in Relaxed Muscle.” ASME 2011 Dynamic Systems and Control Conference and Bath/ASME Symposium on Fluid Power and Motion Control, Volume 2 (2011).
Version
Final published version
Abstract
This paper presents identification and modeling of dynamic ankle mechanical impedance in relaxed muscles. A multi-variable estimation method using a wearable therapeutic robot enabled clear interpretation of dynamic ankle impedance both in the sagittal and frontal planes. Estimation results showed that dynamic ankle behavior apparently cannot be reconciled with a simple 2 nd order model. Measurements in a seated and standing position verified that ankle impedance changes substantially depending on lower-limb posture. Identification results were fitted with a modified Hill model with a mass between the muscle and tendon elements. When coupled with foot inertia, either singly or antagonistically this model successfully captured the dynamic behavior of the ankle impedance both in the seated and standing positions up to 20 Hz. At least a 4th order model having 2 complex zero and 1 complex pole pairs was required to describe relaxed ankle impedance either in the sagittal or frontal plane up to 20Hz. In the seated position, a 6th order model was slightly better than the 4th order model but with the expense of complexity, and a 8th order model might be used to describe dynamic ankle behavior up to 30∼40Hz.
MIT Department
Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/119386
DOI of Published Version
https://doi.org/10.1115/DSCC2011-5976
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.