A Listeria monocytogenes aptasensor on laser inscribed graphene for food safety monitoring in hydroponic water
Name
44187_2024_Article_251.pdf
Size
2.83 MB
Format
Adobe PDF
Checksum (MD5)
fccdd28ae50c78b753d7e603dde36e6b
Author(s) • • • • • •
Cavallaro, Nicholas
Moreira, Geisianny
Vanegas, Diana
Xiang, Dong
Datta, Shoumen P. A.
Gomes, Carmen
McLamore, Eric S.
Date Issued
December 3, 2024
Journal
Discover Food
Publisher
Springer International Publishing
Citation
Cavallaro, N., Moreira, G., Vanegas, D. et al. A Listeria monocytogenes aptasensor on laser inscribed graphene for food safety monitoring in hydroponic water. Discov Food 4, 169 (2024).
Version
Final published version
Abstract
Consumption of fresh produce, such as leafy greens, is often encouraged as part of a healthy diet. Hence, indoor facilities for hydroponic production of leafy greens are increasingly being established. However, fresh produce entails a higher risk of microbial foodborne illnesses than processed foods. Listeria monocytogenes is a major source of fresh produce contamination and is among the leading causes of severe foodborne illnesses in the United States, with a 16% mortality rate. Tools for rapid monitoring are needed for pathogens such as L. monocytogenes to prevent outbreaks. In this manuscript, we have demonstrated the feasibility of a multi-aptamer approach for development of label-free aptasensors targeting L. monocytogenes in irrigation water for lettuce hydroponic production. We use screening studies with surface plasmon resonance to rationally develop mixtures of relevant aptamers for targeting L. monocytogenes. Based on this screening, multiple aptamers targeting extracellular structures on intact L. monocytogenes were tethered to platinum-modified laser inscribed graphene electrodes. This is the first report of a L. monocytogenes biosensor based on laser inscribed graphene. We show that mixing multiple aptamers with varying affinity improves the diagnostic performance over one aptamer alone in complex sample matrices (lettuce hydroponic water). Multi-aptamer biosensors showed high accuracy for L. monocytogenes and were at least three times more selective than Escherichia coli (Crooks, K12, O157:H7) with an accuracy of 85%. The limit of detection (10 CFU/10 mL) is based on data which were significantly different after calibration toward L. monocytogenes or E. coli (Crooks) and validated against gold standard molecular analysis (polymerase chain reaction). Rapid screening of pathogens is a global need to meet food safety and water quality regulations. This study shows the importance of sensors targeting more than one bacterial surface structure in complex samples relevant to the food-water nexus.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Massachusetts Institute of Technology. Auto-ID Laboratory
Terms of Use
Creative Commons Attribution
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1007/s44187-024-00251-z