Strain-induced accelerated asymmetric spatial degradation of polymeric vascular scaffolds
Name
2640.full.pdf
Size
1.18 MB
Format
Adobe PDF
Checksum (MD5)
8273da46fa8dee3603576d06728a374f
Author(s) • • • •
Wang, Peijiang
Ferralis, Nicola
Conway, Claire
Grossman, Jeffrey C.
Edelman, Elazer R
Date Issued
March 2018
Journal
Proceedings of the National Academy of Sciences
Publisher
National Academy of Sciences (U.S.)
Citation
Wang, Pei-Jiang et al. “Strain-Induced Accelerated Asymmetric Spatial Degradation of Polymeric Vascular Scaffolds.” Proceedings of the National Academy of Sciences 115, 11 (February 2018): 2640–2645 © 2018 National Academy of Sciences
Version
Final published version
Abstract
Polymer-based bioresorbable scaffolds (BRS) seek to eliminate long-term complications of metal stents. However, current BRS designs bear substantially higher incidence of clinical failures, especially thrombosis, compared with metal stents. Research strategies inherited from metal stents fail to consider polymer microstructures and dynamics––issues critical to BRS. Using Raman spectroscopy, we demonstrate microstructural heterogeneities within polymeric scaffolds arising from integrated strain during fabrication and implantation. Stress generated from crimping and inflation causes loss of structural integrity even before chemical degradation, and the induced differences in crystallinity and polymer alignment across scaffolds lead to faster degradation in scaffold cores than on the surface, which further enlarge localized deformation. We postulate that these structural irregularities and asymmetric material degradation present a response to strain and thereby clinical performance different from metal stents. Unlike metal stents which stay patent and intact until catastrophic fracture, BRS exhibit loss of structural integrity almost immediately upon crimping and expansion. Irregularities in microstructure amplify these effects and can have profound clinical implications. Therefore, polymer microstructure should be considered in earliest design stages of resorbable devices, and fabrication processes must be well-designed with microscopic perspective. Keywords: bioresorbable scaffolds; Raman spectroscopy; degradation; structural deformation; microstructure heterogeneities; polymer
MIT Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Massachusetts Institute of Technology. Department of Materials Science and Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1073/PNAS.1716420115