Author(s)
Carreiro, Stephanie
•
Smelson, David
•
Ranney, Megan
•
Hayes, Rashelle
•
Horvath, Keith J.
•
Boudreaux, Edwin D.
•
Boyer, Edward W.
•
Picard, Rosalind W.
Date Issued
October 2014
Journal
Journal of Medical Toxicology
Publisher
Springer US
Citation
Carreiro, Stephanie et al. “Real-Time Mobile Detection of Drug Use with Wearable Biosensors: A Pilot Study.” Journal of Medical Toxicology 11.1 (2015): 73–79.
Version
Author's final manuscript
Abstract
While reliable detection of illicit drug use is paramount to the field of addiction, current methods involving self-report and urine drug screens have substantial limitations that hinder their utility. Wearable biosensors may fill a void by providing valuable objective data regarding the timing and contexts of drug use. This is a preliminary observational study of four emergency department patients receiving parenteral opioids and one individual using cocaine in a natural environment. A portable biosensor was placed on the inner wrist of each subject, to continuously measure electrodermal activity (EDA), skin temperature, and acceleration. Data were continuously recorded for at least 5 min prior to drug administration, during administration, and for at least 30 min afterward. Overall trends in biophysiometric parameters were assessed. Injection of opioids and cocaine use were associated with rises in EDA. Cocaine injection was also associated with a decrease in skin temperature. Opioid tolerance appeared to be associated with a blunted physiologic response as measured by the biosensor. Laterality may be an important factor, as magnitude of response varied between dominant and nondominant wrists in a single patient with bilateral wrist measurements. Changes in EDA and skin temperature are temporally associated with intravenous administration of opioids and cocaine; the intensity of response, however, may vary depending on history and extent of prior use.
MIT Department
Massachusetts Institute of Technology. Media Laboratory
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike