Design and Efficacy of a Variable Thickness Transtibial Prosthetic Liner
Name
meyer-cimeyer-MS-MAS-2021.pdf
Description
Thesis PDF
Size
190.79 MB
Format
Adobe PDF
Checksum (MD5)
dd69e0a4059f3842ae8438c003b5b100
Author(s)
Meyer, Christina
Advisor(s)
Herr, Hugh
Date Issued
September 2021
Publisher
Massachusetts Institute of Technology
Abstract
Significant advancements in the socket design process have improved fit and comfort, however, the prosthetic liner remains a largely unaltered component with the potential to mitigate socket pain, discomfort, and irritation. During periods of prolonged knee flexion a conventional liner can cause skin irritation over the top of the patella by applying uncomfortable shear forces to the skin as well as pinching behind the knee. To mitigate these liner irritations, this thesis proposes the use of a novel, subject-specific, variable-thickness liner. To target the knee region, the liner thickness is defined as inversely proportional to the absolute value of the maximum skin strains measured during knee flexion. Areas of high strain correspond to a minimum liner thickness of 2 mm and areas of low strain correspond to a maximum liner thickness of 7mm. Static, 30 minute sit tests were done with conventional, variable and uniform thickness liners. A FLIR thermal camera captured images of the residuum without a liner before and after each test with a 10 minute rest in between tests. I hypothesize that the variable-thickness liner will improve patient comfort for the sit test compared to the uniform and conventional liners evaluated. The results of this pilot study show in the posterior knee region a 0.2% increase in temperature from the variable thickness liner and a 2.8% increase in temperature from the uniform thickness liner. In the anterior patella region there was a 5.5% decrease in temperature from the variable thickness and an average of 0% change in temperature from the uniform thickness liner. These result suggest success of the variable thickness liner at reducing skin irritation and thermal output in regions of high skin strain. A qualitative questionnaire indicated better fit of the novel variable thickness liner compared to the conventional liner. The results of this initial pilot study support the hypothesis, and provide motivation for further testing on a larger study cohort.
MIT Department
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Terms of Use
In Copyright - Educational Use Permitted
Copyright MIT
Persistent DSpace Link