Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Ablation Analysis to Select Wearable Sensors for Classifying Standing, Walking, and Running

Ablation Analysis to Select Wearable Sensors for Classifying Standing, Walking, and Running

Thumbnail Image
Download
Name

sensors-21-00194-v3.pdf

Size

1.59 MB

Format

Adobe PDF

Checksum (MD5)

178bbf16de56e6e868a682429ab8fd20

Download all files submitted through automated deposit
packager-5ff86fe9.zip (1.28 MB)
Author(s)
Gonzalez, Sarah
•
Stegall, Paul
•
Edwards, Harvey
•
Stirling, Leia
•
Siu, Ho Chit
Date Issued
December 30, 2020
Publisher
Multidisciplinary Digital Publishing Institute
Citation
Sensors 21 (1): 194 (2021)
Version
Final published version
Abstract
The field of human activity recognition (HAR) often utilizes wearable sensors and machine learning techniques in order to identify the actions of the subject. This paper considers the activity recognition of walking and running while using a support vector machine (SVM) that was trained on principal components derived from wearable sensor data. An ablation analysis is performed in order to select the subset of sensors that yield the highest classification accuracy. The paper also compares principal components across trials to inform the similarity of the trials. Five subjects were instructed to perform standing, walking, running, and sprinting on a self-paced treadmill, and the data were recorded while using surface electromyography sensors (sEMGs), inertial measurement units (IMUs), and force plates. When all of the sensors were included, the SVM had over 90% classification accuracy using only the first three principal components of the data with the classes of stand, walk, and run/sprint (combined run and sprint class). It was found that sensors that were placed only on the lower leg produce higher accuracies than sensors placed on the upper leg. There was a small decrease in accuracy when the force plates are ablated, but the difference may not be operationally relevant. Using only accelerometers without sEMGs was shown to decrease the accuracy of the SVM.
MIT Department
Massachusetts Institute of Technology. Department of Aeronautics and Astronautics
Lincoln Laboratory
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/131311
DOI of Published Version
https://doi.org/10.3390/s21010194
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.