A micromechanical biosensor with inherently differential readout

Thumbnail Image
Download
Name

56836315-MIT.pdf

Description
Full printable version
Size

11 MB

Format

Adobe PDF

Checksum (MD5)

e575df02332827351993a05bbe7d4b98

Author(s)
Savran, Cagri Abdullah, 1976-
Advisor(s)
Scott R. Manalis.
Date Issued
2004
Publisher
Massachusetts Institute of Technology
Abstract
The ability to detect biomolecules in real-time and without the use of labels has significant benefits for systems biology in terms of cost, time and throughput. Cantilever-based micromechanical sensors detect biomolecular adsorption by means of surface-stress-induced cantilever bending. This technique enables sensitive, scalable and label-free detection of biomolecules in real-time. However, micromachined cantilevers are extremely sensitive to nonspecific chemical effects and temperature changes. This thesis explores a micromechanical sensor that suppresses disturbances by generating an inherently differential signal with respect to a reference surface. The thesis covers the design, fabrication, characterization of the sensor, and its application to protein detection using aptamers; receptor molecules produced in vitro. The sensor is composed of two adjacent cantilevers that form a sensor-reference pair, whereby only the sensing surface is activated with receptor molecules that are specific to the ligand to be detected. The relative, or differential bending between the two cantilevers is directly measured using interferometry. Through direct differential detection, disturbances affecting both cantilevers are suppressed at the measurement level. This eliminates the need for separate detection of each cantilever's motion and off-line processing of the individual signals. At high frequencies, the resolution of the sensor is only limited by its sub-angstrom-level thermomechanical noise. At lower frequencies (frequencies of interest), the resolution is limited by 1/f-type noise which can be reduced by as much as an order of magnitude by direct differential detection, enabling clear observation of receptor-ligand binding
(cont.) reactions in real-time.
Description
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.
Includes bibliographical references (leaves 99-105).
Subjects
Mechanical Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/17944
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.