Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment

Thumbnail Image
Download
Name

1906.00054.pdf

Description
Accepted version
Size

4.07 MB

Format

Adobe PDF

Checksum (MD5)

57208c53797fb7751ea7aad58c6fec23

sword-2020-12-10T17:15:10.original.xml (130 B)
Original SWORD entry document
Author(s)
Rogers, F.
•
Xiao, Min
•
Perez, Kerstin
•
Erjavec, Tyler J
Date Issued
October 2019
Journal
Journal of Instrumentation
Publisher
IOP Publishing
Citation
Rogers, F. et al. “Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment.” Journal of Instrumentation 14, 10 (October 2019): P10009 © 2019 The Author(s)
Version
Author's final manuscript
Abstract
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption efficiency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required ≤4 keV (FWHM) X-ray energy resolution at flight temperatures of -35 to -45°C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/129834
DOI of Published Version
https://doi.org/10.1088/1748-0221/14/10/P10009
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.