Extended Coherence Length and Depth Ranging Using a Fourier-Domain Mode-Locked Frequency Comb and Circular Interferometric Ranging
Name
PhysRevApplied.11.014018.pdf
Size
2.14 MB
Format
Adobe PDF
Checksum (MD5)
4e198fd86c328af2510a9661105a07d8
Author(s) • • •
Lippok, Norman
Siddiqui, Meena
Vakoc, Benjamin
Bouma, Brett E
Date Issued
January 2019
Journal
Physical Review Applied
Publisher
American Physical Society
Citation
Lippok, Norman et al. "Extended Coherence Length and Depth Ranging Using a Fourier-Domain Mode-Locked Frequency Comb and Circular Interferometric Ranging." Physical Review Applied 11, 1 (Janaury 2019): 014018 © 2019 American Physical Society
Version
Final published version
Abstract
Fourier-domain mode locking has been a popular laser design for high-speed optical-frequency-domain imaging (OFDI), but achieving long coherence lengths, and therefore imaging range, has been challenging. The narrow linewidth of a Fourier-domain mode-locked (FDML) frequency-comb (FC) laser could provide an attractive platform for high-speed as well as long-range OFDI. Unfortunately, aliasing artifacts arising from signals beyond the principal measurement depth of the free spectral range have prohibited the use of an FDML FC laser for imaging so far. To make the increased coherence length of an FDML FC laser available, methods to manage such artifacts are required. Recently, coherent circular ranging that uses frequency combs for imaging in much-reduced rf bandwidths has been demonstrated. Here we revisit circular ranging as a tool for making the long coherence length of an FDML FC laser and its use for tissue imaging accessible. Using an acousto-optic frequency shifter (AOFS), we describe an active method to mitigate signal aliasing that is both stable and wavelength independent. We show that an FDML FC laser increases the coherence length by an order of magnitude compared with traditional FDML-laser designs without requiring precise dispersion engineering. We discuss design parameters of a frequency-stepping laser resonator as well as aliasing from a frequency comb and AOFS in OFDI with numerical simulations. The use of circular ranging additionally reduces acquisition bandwidths 15-fold compared with traditional OFDI methods. The FDML FC–AOFS design offers a convenient platform for long-range and high-speed imaging as well as for exploring signal- and image-processing methods in circular ranging.
MIT Department
Institute for Medical Engineering and Science
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1103/PhysRevApplied.11.014018