A performance-based approach to retrofitting unreinforced masonry structures for seismic loads
Name
166269076-MIT.pdf
Description
Full printable version
Size
7.66 MB
Format
Adobe PDF
Checksum (MD5)
75b2dfe64b2372db017aa00c957fa8aa
Author(s)
Bouchard, Keith M. (Keith Michael)
Advisor(s)
Jerome J. Connor.
Alternative Title
Performance-based approach to retrofitting URM structures for seismic loads
Date Issued
2007
Publisher
Massachusetts Institute of Technology
Abstract
The structural inadequacy of existing unreinforced masonry (URM) buildings to resist possible seismic loading is a serious problem in many parts of the United States, including the Northeast and Midwest. The fact that many of these buildings are deemed historic structures or house critical facilities, like firehouses, emphasizes the need for an effective retrofitting program. The Federal Emergency Management Agency published a performance-based design code - FEMA 356 - in 2000 to use for analyzing and retrofitting existing structures. This code includes procedures for URM buildings. This paper applies these performance-based analysis procedures to a URM shear wall and compares the results to a modified analysis proposed by researchers. The wall is then rehabilitated using two common retrofit methods and again analyzed using the code. Recommendations are made for practicing engineers when evaluating URM structures for seismic loads.
Description
Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2007.
Includes bibliographical references (leaves 58-59).
Subjects
Civil and Environmental Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Persistent DSpace Link