Simple filter microchip for rapid separation of plasma and viruses from whole blood

Thumbnail Image
Download
Name

Wang-2012-Simple filter microc.pdf

Size

832.56 KB

Format

Adobe PDF

Checksum (MD5)

c7ee72c8e72de6c99668aa65fa4b0284

Author(s)
Wang, ShuQi
•
Sarenac, Dusan
•
Chen, Michael H.
•
Huang, Shih-Han
•
Giguel, Francoise F.
•
Kuritzkes, Daniel R.
•
Demirci, Utkan
Date Issued
September 2012
Journal
International Journal of Nanomedicine
Publisher
Dove Medical Press
Citation
Wang, ShuQi, Dusan Sarenac, Michael H. Chen, Shih-Han Huang, Francoise F. Giguel, Daniel R. Kuritzkes, and Utkan Demirci. “Simple Filter Microchip for Rapid Separation of Plasma and Viruses from Whole Blood.” International Journal of Nanomedicine (September 2012): 5019.
Version
Final published version
Abstract
Sample preparation is a significant challenge for detection and sensing technologies, since the presence of blood cells can interfere with the accuracy and reliability of virus detection at the nanoscale for point-of-care testing. To the best of our knowledge, there is not an existing on-chip virus isolation technology that does not use complex fluidic pumps. Here, we presented a lab-on-a-chip filter device to isolate plasma and viruses from unprocessed whole blood based on size exclusion without using a micropump. We demonstrated that viruses (eg, HIV) can be separated on a filter-based chip (2-µm pore size) from HIV-spiked whole blood at high recovery efficiencies of 89.9% ± 5.0%, 80.5% ± 4.3%, and 78.2% ± 3.8%, for viral loads of 1000, 10,000 and 100,000 copies/mL, respectively. Meanwhile, 81.7% ± 6.7% of red blood cells and 89.5% ± 2.4% of white blood cells were retained on 2 µm pore–sized filter microchips. We also tested these filter microchips with seven HIV-infected patient samples and observed recovery efficiencies ranging from 73.1% ± 8.3% to 82.5% ± 4.1%. These results are first steps towards developing disposable point-of-care diagnostics and monitoring devices for resource-constrained settings, as well as hospital and primary care settings.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Terms of Use
Creative Commons Attribution-Noncommercial
http://creativecommons.org/licenses/by-nc/3.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/88156
DOI of Published Version
https://doi.org/10.2147/ijn.s32579
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.