  4. A comparison of microfluidic methods for high-throughput cell deformability measurements
This is not the latest version of this item. The latest version can be found here.

A comparison of microfluidic methods for high-throughput cell deformability measurements

Thumbnail Image
Download
Name

nihms-1579163.pdf

Description
Accepted version
Size

1.38 MB

Format

Adobe PDF

Checksum (MD5)

cf3541c433f30fc31b3edcda6e4dd5e0

sword-2021-09-07T17:50:33.original.xml (130 B)
Original SWORD entry document
Author(s)
Urbanska, Marta
•
Muñoz, Hector E
•
Shaw Bagnall, Josephine
•
Otto, Oliver
•
Manalis, Scott R
•
Di Carlo, Dino
•
Guck, Jochen
Date Issued
2020
Journal
Nature Methods
Publisher
Springer Science and Business Media LLC
Version
Author's final manuscript
Abstract
The mechanical phenotype of a cell is an inherent biophysical marker of its state and function, with many applications in basic and applied biological research. Microfluidics-based methods have enabled single-cell mechanophenotyping at throughputs comparable to those of flow cytometry. Here, we present a standardized cross-laboratory study comparing three microfluidics-based approaches for measuring cell mechanical phenotype: constriction-based deformability cytometry (cDC), shear flow deformability cytometry (sDC) and extensional flow deformability cytometry (xDC). All three methods detect cell deformability changes induced by exposure to altered osmolarity. However, a dose-dependent deformability increase upon latrunculin B-induced actin disassembly was detected only with cDC and sDC, which suggests that when exposing cells to the higher strain rate imposed by xDC, cellular components other than the actin cytoskeleton dominate the response. The direct comparison presented here furthers our understanding of the applicability of the different deformability cytometry methods and provides context for the interpretation of deformability measurements performed using different platforms.
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
https://hdl.handle.net/1721.1/136162
DOI of Published Version
10.1038/S41592-020-0818-8
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.