Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Confined Plunging Liquid Jets for Dilution of Brine from Desalination Plants

Confined Plunging Liquid Jets for Dilution of Brine from Desalination Plants

Thumbnail Image
Download
Name

processes-09-00856.pdf

Size

3.01 MB

Format

Unknown

Checksum (MD5)

d91c74035dc3520b858f3a7d5bdd6b50

Download all files submitted through automated deposit
packager-609d3992.zip (2.94 MB)
Author(s)
Shrivastava, Ishita
•
Adams, Edward Eric
•
Al-Anzi, Bader
•
Chow, Aaron Chunghin
•
Han, Jongyoon
Date Issued
May 2021
Journal
Processes
Publisher
Multidisciplinary Digital Publishing Institute
Citation
Processes 9 (5): 856 (2021)
Version
Final published version
Abstract
Confined plunging jets are investigated as potential outfalls for the discharge of desalination brine. Compared to offshore submerged outfalls that rely on momentum to induce mixing, plunging jets released above the water surface utilize both momentum and negative buoyancy. Plunging jets also introduce air into the water column, which can reduce the possibility of hypoxic zones. In contrast to unconfined plunging jets, confined plunging jets include a confining tube, or downcomer, around the jet, which increases the penetration depth of the bubbles and can provide better aeration. However, the presence of this downcomer can hinder mixing with surrounding water. Therefore, laboratory measurements of dilution are reported here and compared to the dilution of unconfined plunging jets. In addition, qualitative observations of bubble penetration depth are also used to discuss aeration potential. For designs that increase the bubble penetration depth as compared to unconfined plunging jets, results show that dilution decreases as the depth of the downcomer is increased. However, it is shown that confined plunging jets can be designed with a short downcomer to provide higher dilution than unconfined jets. The effect of the diameter of downcomer on dilution is also investigated and a non-monotonic effect is observed.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/133163.2
DOI of Published Version
https://doi.org/10.3390/pr9050856