Optical coherence tomography angiography of optic nerve head and parafovea in multiple sclerosis
Name
Fujimoto_Optical coherence.pdf
Size
443.74 KB
Format
Adobe PDF
Checksum (MD5)
20b0da0598445cefdf02f3cb9e4827d9
Author(s) • • • • • • • • •
Wang, Xiaogang
Jia, Yali
Spain, Rebecca
Potsaid, Benjamin M.
Liu, Jonathan Jaoshin
Baumann, Bernhard
Hornegger, Joachim
Fujimoto, James G.
Wu, Qiang
Huang, David
Date Issued
May 2014
Journal
British Journal of Ophthalmology
Publisher
BMJ Publishing Group
Citation
Wang, X., Y. Jia, R. Spain, B. Potsaid, J. J. Liu, B. Baumann, J. Hornegger, J. G. Fujimoto, Q. Wu, and D. Huang. “Optical Coherence Tomography Angiography of Optic Nerve Head and Parafovea in Multiple Sclerosis.” British Journal of Ophthalmology 98, no. 10 (May 15, 2014): 1368–1373.
Version
Author's final manuscript
Abstract
Aims To investigate swept-source optical coherence tomography (OCT) angiography in the optic nerve head (ONH) and parafoveal regions in patients with multiple sclerosis (MS).
Methods Fifty-two MS eyes and 21 healthy control (HC) eyes were included. There were two MS subgroups: 38 MS eyes without an optic neuritis (ON) history (MS −ON), and 14 MS eyes with an ON history (MS +ON). The OCT images were captured by high-speed 1050 nm swept-source OCT. The ONH flow index (FI) and parafoveal FI were quantified from OCT angiograms.
Results The mean ONH FI was 0.160±0.010 for the HC group, 0.156±0.017 for the MS−ON group, and 0.140±0.020 for the MS+ON group. The ONH FI of the MS+ON group was reduced by 12.5% compared to HC eyes (p=0.004). A higher percentage of MS+ON eyes had abnormal ONH FI compared to HC patients (43% vs 5%, p=0.01). Mean parafoveal FIs were 0.126±0.007, 0.127±0.010, and 0.129±0.005 for the HC, MS−ON, and MS +ON groups, respectively, and did not differ significantly among them. The coefficient of variation (CV) of intravisit repeatability and intervisit reproducibility were 1.03% and 4.53% for ONH FI, and 1.65% and 3.55% for parafoveal FI.
Conclusions Based on OCT angiography, the FI measurement is feasible, highly repeatable and reproducible, and it is suitable for clinical measurement of ONH and parafoveal perfusion. The ONH FI may be useful in detecting damage from ON and quantifying its severity.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1136/bjophthalmol-2013-304547