Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Thin-film nano-thermogravimetry applied to praseodymium-cerium oxide films at high temperatures

Thin-film nano-thermogravimetry applied to praseodymium-cerium oxide films at high temperatures

Thumbnail Image
Download
Name

document(1).pdf

Description
Published version
Size

1.68 MB

Format

Adobe PDF

Checksum (MD5)

8c77fd7df84b9a05879c1e9723528a42

sword-2019-09-24T18:26:41.original.xml (130 B)
Original SWORD entry document
Author(s)
Schröder, Sebastian
•
Fritze, Holger
•
Bishop, Sean
•
Chen, Di
•
Tuller, Harry L
Date Issued
2018
Journal
Applied Physics Letters
Publisher
AIP Publishing
Version
Final published version
Abstract
© 2018 Author(s). High precision measurements of oxygen nonstoichiometry δ in thin film metal oxides MaOb±δ at elevated temperatures and controlled oxygen partial pressures pO2 are reported with the aid of resonant microbalances. The resonant microbalances applied here consisted of y-cut langasite (La3Ga5SiO14) and CTGS (Ca3TaGa3Si2O14) piezoelectric resonators, operated in the thickness shear mode at ∼5 MHz. Measurements of variations in δ of Pr0.1Ce0.9O2-δ (PCO) films are reported for the oxygen partial pressure range from 10-8 bar to 0.2 bar at 700 °C, and these results were found to be in good agreement with previously reported oxygen nonstoichiometry δ data derived from chemical capacitance studies. The PCO thin-films were deposited via pulsed laser deposition on both sides of the resonators, whose series resonance frequency was tracked, converted into mass changes and, finally, into nonstoichiometry. The nonstoichiometry was observed to reach a plateau as the oxygen partial pressure dropped below about 10-5 bar, the behavior being attributed to the full reduction of Pr to the trivalent state. These resonators enable stable operation up to temperatures above 1000 °C, thereby maintaining high mass resolution suitable for determining oxygen nonstoichiometry variations in thin films deposited on such resonators. For the given experimental conditions, a mass resolution of ∼50 ng was achieved at 700 °C with the CTGS resonator.
MIT Department
Massachusetts Institute of Technology. Department of Materials Science and Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
https://hdl.handle.net/1721.1/134934
DOI of Published Version
https://doi.org/10.1063/1.5025389
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.