Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Libraries
  3. MIT Theses
  4. Graduate Theses
  5. Closed-loop controlled filament stretching and break-up of polymer solutions

Closed-loop controlled filament stretching and break-up of polymer solutions

Thumbnail Image
Download
Name

66910341-MIT.pdf

Description
Full printable version
Size

12.85 MB

Format

Adobe PDF

Checksum (MD5)

ffcd698c2e06d34389629e06e9e4aa12

Author(s)
Yeh, Roger, 1980-
Advisor(s)
Gareth H. McKinley.
Date Issued
2005
Publisher
Massachusetts Institute of Technology
Abstract
A constant true (radial) strain rate filament stretching experiment has been the Holy Grail of extensional rheological studies. These experiments are performed on a Filament Stretching Extensional Rheometer (FiSER). A filament stretching experiment is the only direct way of measuring the extensional viscosity of a fluid. Previous attempts to achieve constant rate stretching have required tedious and iterative processes, which relied on the data of previous experiments to generate an axial profile that would result in a constant true strain rate experiment. This study presents a method to actively control the axial strains via the utilization of radial strain feedback. The first method we tried was an "Euler 1st order approximation," in which the ratio of the axial and radial strains is calculated at each time-step to determine the axial strain necessary at the next time-step to maintain a constant radial strain rate. This method worked, but was limited by how accurate this "ratio" of strains could be calculated. The "ratio" becomes unstable when the change in strain per time-step reaches the same order of noise. To fix this problem, we implemented a least squares linear regression scheme.
(cont.) With this algorithm, we were able to reach radial strains of ... with strain rates of ... . Finally, we compared stretch-to-break (STB) experiments of a Newtonian fluid, styrene oil, to theoretical model. These experiments are also done on FiSER with the nominal strain rate held constant, generally very low (...). For a Newtonian fluid, the diameter decay can be determined analytically. We repeat the same with a weakly elastic fluid. STPĀ® motor oil.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.
Includes bibliographical references (p. 113-118).
Subjects
Mechanical Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/33908
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.