Author(s)
Jang, Siyoul
•
Tichy, John A.
Date Issued
1997
Journal
International Journal of Rotating Machinery
Publisher
Hindawi Publishing Corporation
Citation
Jang, Siyoul, and John A. Tichy. “Internal Damper Characteristics of Rotor System with Submerged ER Fluid Journal Bearing.” International Journal of Rotating Machinery 3, no. 1 (1997): 61–71. © 1997 Hindawi Publishing Corporation
Version
Final published version
Abstract
Electro-Rheological (ER) fluid behavior is similar to Bingham fluid’s. Only when the shear stress magnitude of ER fluid exceeds the yield stress, Newtonian flow results. Continuous shear strain rate equation about shear stress which simulates Bingham-like fluid shows viscosity variations. Shear yield stress is controlled by electric fields. Electric fields in circumferential direction around the journal are also changeable because of gap distance. These values make changes of spring and damping coefficients of journal bearings compared to Newtonian flow case. Implicit viscosity variation effects according to shear strain rates of fluid are included in generalized Reynolds' equation for submerged journal bearing. Fluid film pressure and perturbation pressures are solved using switch function of Elord's algorithm for cavitation boundary condition. Spring and damping coefficients are obtained for several parameters that determine the characteristics of ER fluids under a certain electric field. From these values stability region for simple rotor-bearing system is computed. It is found that there are no big differences in load capacities with the selected electric field parameters at low eccentric region and higher electric field can support more load with stability at low eccentric region.
MIT Department
Massachusetts Institute of Technology. Laboratory for Manufacturing and Productivity
Terms of Use
Creative Commons Attribution
http://creativecommons.org/licenses/by/2.0
Persistent DSpace Link
http://hdl.handle.net/1721.1/96135
DOI of Published Version
https://doi.org/10.1155/S1023621X97000079
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.